Dynamic- Modal Analysis on Genset Package

Project Scope


  • Identify natural frequencies and mode shapes of the genset package

  • Improve critical modes – specifically vertical bending and twisting frequencies


Business Challenges


  • Accurately tune mass and center of gravity for assemblies and overall package

  • Maintain low node count to reduce simulation time


ARi’s Solutions


  • Conducted modal analysis to extract natural frequencies and mode shapes

  • Developed Campbell diagram to pinpoint resonance risks

  • Performed design iterations to meet frequency targets


ARi’s Value Proposition


  • Improved Structural Dynamics: Bending mode frequency increased from 24.2 Hz to 32.5 Hz, twisting mode from 49.2 Hz to 58.4 Hz

  • Optimized Design Through Iteration: Multiple refinements ensured reliable and efficient performance

  • Faster Simulation Cycles: Controlled model size helped reduce solving time

  • Reduced Vibration Risk: Final design avoided resonance, improving equipment longevity


Download
Case Study

Download Case Study